Facebook Pixel

NAVIEN TANKLESS WATER HEATERS 30022123A Remote Control

Special Price $76.74 Regular Price $88.25
Out of stock
SKU
30022123A
The Navien Tankless Water Heaters 30022123A Water Adjustment Valve & Flow Sensor are the parts that enhance the efficiency of Navien tankless water heaters. This durable plastic valve regulates both temperature and water flow to give you the optimum heating convenience. This appliance can be adjusted to different home requirements since it has a temperature range of 32°F to 158°F. Since the control of the heating system herein requires constant hot water deli and avoiding overheating, therefore is crucial in enhancing user comfort. This sturdy plastic valve controls temperature and water flow to provide the better possible heating effectiveness.
https://www.partshnc.com/media/catalog/product/3/0/30022123a.jpg

Specifications

  • Weight: 0.61 lbs
  • Type: Water Adjustment Valve
  • Material: Durable Plastic
  • Temperature Range: 32°F to 158°F

PRODUCT OVERVIEW:
A water adjustable valve and flow sensor assembly regulates water passage while detecting flow within a tankless water heating system. The Navien 30022123A is an OEM combination valve and flow sensor assembly designed for compatible Navien equipment. Its flow-sensing function detects water movement when hot water demand occurs, while the adjustable valve controls water flow through the internal circuit. These combined functions support heating demand detection and water flow regulation during operation.

INTEGRATED VALVE AND SENSOR OPERATION:
The assembly combines water flow detection with adjustable flow control. When water moves through the system, the flow sensor detects the movement and provides a signal to initiate the heating process. The adjustable valve regulates the water passage to manage flow volume through the equipment. Together, these functions support demand-based heating operation and controlled water delivery.

REPLACEMENT GUIDELINES:
Replace the Navien 30022123A when the assembly fails to detect incoming water flow, does not regulate water passage properly, develops leakage, or restricts normal water circulation. A malfunctioning assembly may prevent the equipment from responding to hot water demand or contribute to inconsistent outlet temperatures. Have a qualified technician inspect the sensor, valve, electrical connections, and water circuit before determining whether the complete assembly requires replacement. Before purchasing, verify the part number and all relevant specifications against the original equipment documentation to ensure the replacement matches the system requirements.

COMMON FAILURE SYMPTOMS:

  • Water heater fails to initiate heating when a hot water tap is opened.
  • Inconsistent hot water temperatures during use.
  • Reduced water flow through connected fixtures.
  • Water leakage around the valve and sensor assembly.
  • Delayed heating response after hot water demand begins.

EQUIPMENT COMPATIBILITY:
The Navien 30022123A is intended for compatible Navien tankless water heating equipment requiring a combined water adjustable valve and flow sensor assembly. Confirm the part number and component type against the original equipment documentation before selecting a replacement. For exact compatible equipment models, refer to the manufacturer's documentation. Do not assume compatibility based on the manufacturer name alone.

TECHNICAL SPECIFICATIONS:
Product Identification:
Brand: Navien Tankless Water Heaters
Part Number: 30022123A
Component Type: Water Adjustable Valve and Flow Sensor Assembly

Write Your Own Review
You're reviewing:NAVIEN TANKLESS WATER HEATERS 30022123A Remote Control
Your Rating
Customer Questions
How does the flow sensor help a tankless water heater respond to hot water demand?

It detects water movement through the system and sends a signal that allows the equipment to recognize a demand for heating.

What is the purpose of combining a flow sensor with an adjustable valve?

The flow sensor detects water movement, while the adjustable valve regulates water passage. Together, they provide flow detection and control within one assembly.

Can a faulty flow sensor prevent a tankless water heater from starting?

Yes. If the sensor fails to detect water movement or transmit the required signal, the equipment may not recognize a hot water demand.

How can a malfunctioning adjustable valve affect water delivery?

A valve that restricts or incorrectly regulates water passage may contribute to reduced flow or inconsistent hot water delivery.

What should be inspected before replacing the complete valve and flow sensor assembly?

A technician should inspect water flow, sensor response, electrical connections, and valve operation to determine whether the assembly is responsible for the problem.