Facebook Pixel

Bradford White 265-46024-00 Natural Gas Burner Assembly

Special Price $1,120.46 Regular Price $1,243.71
In stock
SKU
265-46024-00
Bradford White's 265-46024-00 natural gas burner assembly is developed particularly for Bradford White household gas water heaters. This essential part is necessary for the safe and effective burning of natural gas to produce heat for water heating. An igniter, a flame sensor, and a burner tube usually make up the assembly. For effective burning, the burner tube makes sure that the gas and air are properly mixed. The flame sensor continuously monitors the flame and, if the flame extinguishes, instantly cuts off the gas supply, preventing safety problems. The igniter supplies the spark that starts the burning process. Optimised performance and compatibility are guaranteed when a genuine Bradford White part is used to replace a defective 265-46024-00.
https://www.partshnc.com/media/catalog/product/2/6/265-46024-00.jpg
Manufacturer Name: Bradford White
Product Number: 265-46024-00
OEM Part Number: 265-46024-00
Product Description: Burner Assembly Natural
Weight:9.76lbs/4427.06g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Bradford White 265-46024-00 Natural Gas Burner Assembly
Your Rating
Customer Questions
What maintenance is required for the Bradford White 265-46024-00 Burner Assembly?

Regularly inspect the burner for soot, debris, or corrosion. Clean the burner ports and check ignition components for proper function. Ensure gas connections are tight and free of leaks. Proper care prevents flame instability and unsafe operation.

What are common issues with the Bradford White 265-46024-00 Burner Assembly?

  • Flame irregularities or uneven burning.
  • Ignition failure or delayed lighting.
  • Gas leaks from connections.
  • Soot buildup causing reduced efficiency.

Installation Steps

Step 1: Turn off gas supply and disconnect power to the unit for safety.

Step 2: Remove the access panel and locate the existing burner assembly.

Step 3: Disconnect gas line and ignition wires carefully.

Step 4: Unscrew and remove the old burner assembly.

Step 5: Install the new burner assembly securely and reconnect gas line and wiring.