Facebook Pixel

Danfoss 082H5006 N/O Actuator 24V AB-QM

Special Price $366.91 Regular Price $407.27
In stock
SKU
082H5006
The Danfoss 082H5006 N/O AB-QM Actuator is designed to be used in HVAC equipment. It is appropriate for usage of up to 50/60 Hz. This actuator has 24 volts, 9 watts of power and a volume of up to 1.755 liters. The fine-tuning of this regulation enhances energy conservation, maintains a constant interior temperature as well as enhances the performance of the system. Benefits include compatibility with the current systems since it use standard electricity, energy efficiency since it modulate the energy used accurately and protection of HVAC parts from damage through control. This actuator is better suited for areas where a stable and efficient climate will be required.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/8/082h5006_danfoss_partshnc.png

Specifications

  • Weight: 2.16 lbs
  • Actuator type: Electrical
  • Frequency: 50/60 Hz
  • Type: AME 13 SU-1
  • Volume: 1.755 Liter
  • Voltage: 24 V
  • Control signal type: Modulating/3-point
  • Power consumption: 9 W
Manufacturer Name: Danfoss
Product Number: 082H5006
OEM Part Number: 082H5006
Product Description: 24V N/O Ab-Qm Actuator
Weight:2.16lbs/979.76g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Danfoss 082H5006 N/O Actuator 24V AB-QM
Your Rating
Customer Questions
What maintenance is required for the Danfoss 082H5006 Actuator?

Periodically check the actuator for smooth movement and proper operation. Clean any dust or debris around the mechanism, and ensure wiring connections are secure. Verify correct voltage supply, and always disconnect power before servicing to prevent electrical hazards.

What are common issues with the Danfoss 082H5006 Actuator?

  • Failure to open or close fully.
  • Erratic or slow response to control signals.
  • Electrical coil malfunction or short circuits.
  • Mechanical sticking due to debris or wear.

Installation Steps

Step 1: Turn off all power to the HVAC system to prevent electric shock.

Step 2: Remove the old actuator from the valve by loosening the mounting screws.

Step 3: Position the new actuator onto the valve stem.

Step 4: Secure the actuator with screws and ensure it is properly aligned.

Step 5: Connect the power and control wires according to the wiring diagram.

Step 6: Restore power and run a test cycle to verify proper operation.