The Trane COM8288 Compressor is a robust compressor suited for handling large loads of commercial and industrial cooling utility more than likely running of an R-22 refrigerant. Inside, pistons or blades quickly compress refrigerant gas up to 3500 RPM raising pressure and lowering temperature down to 20°F. This 7.5-ton capacity compressor is quite sturdy. It has brazed stub tubes for the connection of refrigerant circulation. This Compressor is an essentialcomponent of air conditioning systems. By effectively compressing refrigerant, it produces the required process for heat exchange. It is the compressed refrigerant that flows in the system to remove heat from a building’s interior and discharge it to the outside using R-22 refrigerant.
Manufacturer:
https://www.partshnc.com/media/catalog/product/c/o/com8288.jpg

Specifications

  • Voltage: 230V
  • Height: 24
  • Phase: Three
  • Connection Type: Brazed, Stub Tube
  • Oil Type: Mineral Oil
  • Refrigerant: R-22
  • Speed: 3500 RPM
  • Type: Hermetic, Positive Displacement
  • Length: 28"
  • Frequency: 60 Hz
  • Material: Steel Shell
  • Refrigeration Capacity: 7.5Ton
  • Weight: 143lbs
  • Temperature Rating: 20°F
Manufacturer Name: Trane
Product Number: COM8288
OEM Part Number: COM8288
Product Description: 230V3ph 7.5Ton Compressor
Weight:143lbs/64863.66g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Trane COM8288 Compressor 230V 3-Phase 7.5Ton
Your Rating
Customer Questions
What maintenance is required for the Trane COM8288 Compressor?

Inspect electrical connections and tighten terminals regularly. Maintain proper refrigerant levels and ensure clean airflow to prevent overheating. Regular servicing improves efficiency and reduces breakdown risk. Always isolate power before servicing for safety.

What are common issues with the Trane COM8288 Compressor?

  • Refrigerant leak issues.
  • Compressor overheating.
  • Electrical contactor failure.
  • Phase imbalance in operation.
  • Reduced cooling capacity.
  • Excessive vibration and noise.

Installation Steps

Step 1: Switch off main power and isolate electrical supply, release refrigerant pressure for safety.

Step 2: Check compatibility of refrigerant lines and electrical ratings.

Step 3: Mount compressor on stable vibration-damped base and secure fasteners.

Step 4: Connect wiring per diagram and confirm proper grounding.

Step 5: Perform vacuum, leak test, then start up and monitor operation for abnormal noise or pressure.