Facebook Pixel

Reznor 96383 4-Blade Fan 22" Diameter 35° Angle 1/2" Bore CW

Special Price $147.70 Regular Price $169.86
In stock
SKU
96383
The Reznor 96383 4-Blade Fan works through the process of circulating air within the HVAC system to maintain the right temperatures in the rooms. It comes with a diameter of 22 inches and a pitch angle of 35 degrees to ensure it increases the flow of air, cutting power consumption and improving the performance of the system. When it turns in a clockwise manner, it produces a continuous flow of air, which is useful in circulating heat or cool air in a given area.
Manufacturer:
https://www.partshnc.com/media/catalog/product/9/6/96383.jpg

Specifications

  • Type: Fan Blade
  • Number of Blades: 4
  • Diameter: 22"
  • Blade Angle: 35°
  • Bore Size: 1/2"
  • Rotation: Clockwise (CW)

PRODUCT OVERVIEW:
Maintains effective air circulation within compatible Reznor heating and ventilation equipment, helping distribute heated air throughout the system. The Reznor 96383 4-Blade Fan is a genuine OEM component with a 22" diameter, 35° blade angle, and clockwise rotation. Its four-blade configuration and 1/2" bore support the specified motor connection and airflow requirements for the intended equipment.

BLADE PITCH:
Angled blade surfaces generate airflow as the fan rotates, moving air through the connected heating equipment. The blade arrangement helps maintain steady air movement and supports effective heat distribution throughout the system. Proper blade alignment is important for consistent airflow.

FAN ROTATION:
Proper fan operation depends on the motor transferring rotational force to the fan assembly. The connection between the hub and motor shaft helps keep the blade securely positioned and rotating smoothly. Maintaining this connection supports stable operation and consistent airflow.

REPLACEMENT GUIDELINES:
Replace the Reznor 96383 4-Blade Fan when its blades become bent, cracked, or damaged, or when imbalance affects smooth rotation. Replacement may also be necessary if the hub or bore becomes worn and cannot maintain a secure motor shaft connection. Have a qualified HVAC technician inspect the fan blade, motor shaft, and mounting arrangement before replacement.

COMMON FAILURE SYMPTOMS:

  • Fan blade develops cracks or visible deformation
  • Excessive vibration occurs during operation
  • Unusual noise comes from the fan assembly
  • Airflow becomes weak or uneven
  • Fan hub or bore shows signs of wear

EQUIPMENT COMPATIBILITY:
The Reznor 96383 is a genuine OEM four-blade fan designed for compatible Reznor heating and ventilation equipment. Its 22" diameter, 35° blade angle, clockwise rotation, and 1/2" bore must match the original fan assembly requirements. Confirm the existing part number and motor rotation before purchasing.

TECHNICAL SPECIFICATIONS:
Brand: Reznor
Part Number: 96383
Product Type: Fan Blade
Number of Blades: 4
Diameter: 22"
Blade Angle: 35°
Bore Size: 1/2"

Write Your Own Review
You're reviewing:Reznor 96383 4-Blade Fan 22" Diameter 35° Angle 1/2" Bore CW
Your Rating
Customer Questions
What maintenance is required for the Reznor 96383 Fan Blade?

Regularly inspect the fan blades for dust buildup and debris, and clean with a soft cloth. Check for loose bolts or misalignment to prevent vibration. Lubricate bearings as needed to maintain smooth operation and ensure safety when working around moving parts.

What are common issues with the Reznor 96383 Fan Blade?

  • Uneven or wobbly rotation.
  • Excessive noise during operation.
  • Reduced airflow efficiency.
  • Bearing wear or motor overheating.

What does the Reznor 96383 4-Blade Fan do?

The Reznor 96383 moves air through the connected assembly when driven by a compatible shaft, supporting the equipment's intended airflow function.

How can I identify the correct replacement for the Reznor 96383?

Compare the existing fan's part number with the equipment parts documentation and verify that the replacement matches the required mechanical configuration.

Why is the 35° blade angle important when selecting a replacement fan?

The blade angle affects how the fan blades interact with the surrounding air. The replacement should match the blade angle specified for the intended assembly.

What does CW mean on the Reznor 96383 Fan?

CW means clockwise rotation. The replacement fan must rotate in the direction required by the connected drive and equipment configuration.

Can another 22-inch fan with a 1/2-inch bore replace the Reznor 96383?

Not necessarily. The blade count, blade angle, rotation direction, mounting arrangement, and equipment requirements must also match before selecting a replacement.

Why is the blade angle important for the Reznor 96383 fan?

The blade angle determines the orientation for moving air through the equipment and must match the specified fan design.

Does the Reznor 96383 require clockwise motor rotation?

Yes. The fan blade is designed for clockwise rotation, so the motor's rotation direction must match this requirement.

What should be matched when replacing the Reznor 96383 fan?

Verify the replacement's part number, blade configuration, blade angle, rotation direction, and mounting dimensions against the existing fan and the equipment manufacturer's requirements.

What should be inspected when maintaining this four-blade fan?

Check the blades, hub, and mounting bore for cracks, deformation, looseness, or buildup that could affect balance and airflow.

Can an incorrectly sized fan blade affect heater performance?

Yes. An incorrect blade size, angle, or rotation direction can disrupt airflow and interfere with the heater's intended operation.

Installation Steps

Step 1: Disconnect power to the unit at the main supply to ensure safe handling.

Step 2: Remove the protective cover or grille to expose the fan blade.

Step 3: Loosen the securing screw on the blade hub and slide the old blade off the shaft.

Step 4: Install the new blade onto the shaft, confirming proper clockwise orientation and alignment.

Step 5: Secure the blade firmly, reattach the cover, and restore power to verify proper operation.