The Honeywell TR23 Temperature Sensor is a component that can be used in different HVAC systems. This sensor has override functionality, permitting manual adjustments of temperature within a defined range 55°F to 85°F. It is based on the resistance variation with temperature change. The resistance of the sensor decreases with increasing temperature. The change in resistance is interpreted by the control board of the HVAC system and causes operation of the system to be adjusted in order to maintain the desired temperature. Applications of the TR23 sensor include furnaces, air conditioners, heat pumps and thermostats.
https://www.partshnc.com/media/catalog/product/t/r/tr23_1.jpg

Specifications

  • Type: Temperature Sensor
  • Temperature Range: 55°F to 85°F
  • Resistance: 20K Ohms

Product Overview:
Accurate room-temperature sensing helps building control systems monitor indoor conditions and maintain the desired comfort levels. The Honeywell TR23 Temperature Sensor With Override 55°F-85°F 20K Ohm OEM is designed to provide a temperature-dependent resistance signal to a connected HVAC controller. Its built-in override function allows users to initiate a temporary change in the control system's operating mode, while the adjustment range supports local temperature setting.

Resistance Output:
The sensor detects changes in room temperature and varies its resistance according to its 20K Ohm sensing characteristic. The connected controller interprets this resistance signal to determine the space temperature and make appropriate HVAC control adjustments.

Override Control:
The temperature adjustment allows users to select a desired setting within the specified 55°F–85°F range. The override function provides a local means of requesting a temporary change in system operation, subject to the configuration of the connected controller.

Replacement Guidelines:
Replace the Honeywell TR23 Temperature Sensor With Override 55°F-85°F 20K Ohm when temperature readings become inaccurate, the controller receives an inconsistent sensor signal, or the override function stops responding. Replacement may also be necessary if the sensor housing, adjustment mechanism, or wiring connections become damaged. Have a qualified HVAC controls technician verify the sensor input and wiring before replacement.

Common Failure Symptoms:

  • Room-temperature readings become inaccurate or unstable.
  • The connected controller receives an incorrect resistance signal.
  • Temperature adjustments do not produce the expected response.
  • The override function fails to activate.
  • Sensor wiring or housing shows physical damage.

Equipment Compatibility:
The Honeywell TR23 Temperature Sensor With Override 55°F-85°F 20K Ohm OEM replacement component is intended for HVAC control systems designed for a 20K Ohm temperature sensor with the required override functionality. Verify the existing part number, sensor resistance characteristic, controller input requirements, wiring, and mounting arrangement before replacement.

Technical Specifications:
Brand: Honeywell
Part Number: TR23
Product Type: Temperature Sensor
Sensing Resistance: 20 kΩ
Temperature Adjustment Range: 55°F–85°F
Feature: Override

Write Your Own Review
You're reviewing:Honeywell TR23 Temperature Sensor W/Override 55°F-85°F 20K Ohm
Your Rating
Customer Questions
What is the function of the Honeywell TR23 Temperature Sensor With Override?

It senses room temperature within its 55°F–85°F range and provides an override function for compatible HVAC controls.

How does the 20K Ohm sensing element support the TR23 Temperature Sensor?

Its 20K Ohm sensing element provides temperature-dependent resistance signals to the connected control system.

Which specifications determine compatibility with the Honeywell TR23 Temperature Sensor?

Check the 20K Ohm sensor resistance, 55°F–85°F temperature range, override requirements, wiring connections, and controller compatibility.

What operating problems indicate that the TR23 Temperature Sensor needs replacement?

Replace it when temperature sensing becomes inaccurate or the override function no longer responds correctly.

What are common signs of a failing room temperature sensor?

Common signs include inaccurate temperature readings, inconsistent HVAC operation, delayed temperature response, and unresponsive override controls.