Lochinvar & A.O. Smith 100110108 15kW Heating Element 208V

Special Price $456.24 Regular Price $506.43
In stock
SKU
100110108
The Lochinvar & A.O. Smith 100110108 Heating Element is a high 208V, 15kW heating element for specific Lochinvar and A.O. Smith water heaters. This heating element works through the use of electricity deposits where heath is produced directly in the water, to a required temperature. Its construction makes it more resilient to tough conditions and its reliability is not in doubt. Suitable for residential and commercial HVAC use, this heating element improves energy efficiency, offers fast heat up time, and results in more continuous availability of hot water, hence increasing the performance and perceived satisfaction by the user of the water heater.
https://www.partshnc.com/media/catalog/product/0/0/0038305_0.jpg

Specifications

  • Type: Heating Element
  • Voltage: 208V
  • Power: 15kW
Manufacturer Name: Lochinvar & A.O. Smith
Product Number: 100110108
OEM Part Number: 100110108
Product Description: 208V 15Kw Heating Element
Weight:3.07lbs/1392.53g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Lochinvar & A.O. Smith 100110108 15kW Heating Element 208V
Your Rating
Customer Questions
What maintenance is required for the Lochinvar & A.O. Smith 100110108 Heating Element?

Regularly inspect the heating element for scale buildup, corrosion, and loose electrical connections. Clean or descale as needed to maintain efficient heat transfer. Ensure power is disconnected before servicing. Periodic checks can prevent overheating and enhance operational safety.

What are common issues with the Lochinvar & A.O. Smith 100110108 Heating Element?

  • Scaling or mineral buildup on heating element reducing efficiency.
  • Electrical connection failures or loose wiring causing intermittent heating.
  • Element burnout or reduced heating output over time.
  • Overheating due to thermostat malfunction or poor water flow.

Installation Steps

Step 1: Turn off power at breaker and apply lockout/tagout before starting; verify no electricity.

Step 2: Shut water supply and partially drain tank below element level to avoid flooding.

Step 3: Remove access panel and carefully disconnect wiring, noting connections.

Step 4: Unscrew old heating element, and install new element securely, ensure seal.

Step 5: Reconnect wiring, refill tank, check for leaks, allow air purge, then restore power and test.