Facebook Pixel

MARS 12838 Oval Run Capacitor 50/5 MFD 370V

Special Price $23.88 Regular Price $31.05
In stock
SKU
12838
The MARS 12838 Oval Run Capacitor 50/5 MFD 370V is an electrical part to stabilize working of the motor and to sustain the flow of the constant electric current that is used in the HVAC systems. This capacitor works by charging and discharging electrical energy, which assists the motors in starting and running efficiently. It is commonly fitted in commercial and residential air conditioning and refrigeration systems, and plays a vital role in the concept that underpins the entire system, which is balancing the voltage and supporting the stable operation of the motor.
Manufacturer:
https://www.partshnc.com/media/catalog/product/1/2/12838_mars_partshnc.jpg
Manufacturer Name: MARS
Product Number: 12838
OEM Part Number: 12838
Product Description: 50/5Mfd 370V Oval Run Capac.
Weight:0.67lbs/303.91g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:MARS 12838 Oval Run Capacitor 50/5 MFD 370V
Your Rating
Customer Questions
What maintenance is required for the MARS 12838 Run Capacitor?

Regularly inspect the capacitor for bulging, leaks, or corrosion on terminals. Ensure electrical connections remain tight and free from dirt or oxidation. Proper maintenance helps prevent system failure and ensures efficient operation. Always disconnect power before handling to avoid electrical hazards.

What are common issues with the MARS 12838 Run Capacitor?

  • Capacitor failing to hold charge.
  • Swollen or bulging casing.
  • systems unit not starting properly.
  • Intermittent motor operation.
  • Overheating during use.
  • Electrical leakage or short circuit symptoms.

Installation Steps

Step 1: Turn off power at breaker and check no voltage present using a multimeter after disconnecting unit.

Step 2: Discharge old capacitor using insulated resistor tool and safely short terminals.

Step 3: Label and disconnect wires from existing capacitor terminals, noting connections.

Step 4: Install new capacitor matching terminal markings.

Step 5: Secure capacitor, reconnect wires, restore power, test HVAC operation, check for proper cooling.