The Automation Components Inc (ACI) 122880 Thermistor is an essential component of HVAC systems. The sensor system is designed with a 10K ohm temperature sensor that delivers top performance. The part works well with both 0-5/0-10 VDC and 4-20 mA input signals for system installation. The part uses negative temperature coefficient technology to measure temperature accurately while keeping delay times low. The benefits include performing well in demanding conditions, better construction which maintains stability and durability, and increased efficiency of system equipment.
https://www.partshnc.com/media/catalog/product/1/2/122880.jpg

Specifications

  • Type: Thermistor
  • Resistance: 10K
  • Input Signals: 0-5/0-10 VDC 4-20mA
Manufacturer Name: Automation Components Inc (ACI)
Product Number: 122880
OEM Part Number: 122880
Product Description: 0-5/0-10Vdc/4-20Ma 10K Thrmstr
Weight:1.22lbs/553.38g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Automation Components Inc (ACI) 122880 Thermistor 10K 0-5/0-10 VDC 4-20mA
Your Rating
Customer Questions
What maintenance is required for the Automation Components Inc (ACI) 122880 Thermistor?

Regularly inspect the thermistor for dust, corrosion, or loose connections. Ensure wiring is secure and signals are within expected ranges. Calibration checks can maintain accuracy. Avoid exposing the device to extreme conditions that could affect readings.

What are common issues with the Automation Components Inc (ACI) 122880 Thermistor?

  • Inaccurate temperature readings.
  • Signal drift or instability.
  • Wiring or connector failures.
  • Noise interference affecting voltage output.

Installation Steps

Step 1: Turn off power to the HVAC system before installation to prevent electrical shock.

Step 2: Mount the thermistor in the desired duct or wall location with proper airflow exposure.

Step 3: Connect the power and output wiring according to the manufacturer’s wiring diagram.

Step 4: Configure the output settings for 0-5V, 0-10V, or 4-20mA as required.

Step 5: Restore power, test the signal output, and verify accurate temperature readings for safe operation.