The International Comfort Products 1193219 Thermal Expansion Valve Kit is intended for use with HVAC systems that utilize R410A refrigerant. This component regulates the refrigerant of amount that goes into the evaporator coil to provide the most effective cooling solution. Thus, the TXV helps to avoid compressor damage and improve system performance when the correct superheat level is maintained. This kit is recommended for air conditions and heat pump thus stabilizing the performance while increasing the energy standard. In addition to improving temperature regulation, lowering energy use, and increasing equipment durability, the TXV is an essential component of HVAC systems.
https://www.partshnc.com/media/catalog/product/1/1/1193219.jpg

Specifications

  • Type: Thermal Expansion Valve (TXV) kit
  • Refrigerant: R410A
Manufacturer Name: International Comfort Products
Product Number: 1193219
OEM Part Number: 1193219
Product Description: Txv Valve R410a
Weight:0lbs/0g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:International Comfort Products 1193219 Thermal Expansion Valve (TXV) Kit R410A
Your Rating
Customer Questions
What maintenance is required for the International Comfort Products 1193219 Thermal Expansion Valve Kit?

Inspect refrigerant lines and sensing bulb for accurate superheat control. Clean inlet screen and verify refrigerant charge to ensure proper flow. Check for leaks, secure fittings, and follow the safety procedures.

What are common issues with the International Comfort Products 1193219 Thermal Expansion Valve Kit?

  • Inconsistent cooling due to improper superheat regulation.
  • Clogged inlet screen restricting refrigerant flow.
  • Faulty sensing bulb causing erratic valve operation.
  • Refrigerant leaks leading to reduced system efficiency.
  • Valve sticking or failing under heavy load conditions.

Installation Steps

Step 1: Turn off power and recover refrigerant safely using approved recovery equipment

Step 2: Remove old TXV and clean line set thoroughly

Step 3: Install new valve ensuring correct refrigerant flow direction

Step 4: Braze connections using nitrogen purge to prevent oxidation

Step 5: Insulate bulb and secure sensing line properly

Step 6: Vacuum system and leak test carefully

Step 7: Recharge refrigerant to manufacturer specifications

Step 8: Wear PPE and follow HVAC safety procedures always.