Facebook Pixel

Bard HVAC 8403-062 Remote Air Sensor 10K Ohm

Special Price $82.12 Regular Price $94.43
In stock
SKU
8403-062
The Bard HVAC 8403-062 Remote Air Temperature Sensor 10K Ohm is a sensing part thermistor that is used to measure temperature in HVAC systems. It identifies the ambient conditions and transmits a matching resistance signal to the system control or thermostat so that it can provide precise temperature regulation and comfort control. This sensor is to supply or return air to paths or occupied spaces to make sure that the unit reacts appropriately to the real air conditions. In the appropriate temperature control and effective cycling of the system when it is used in normal heating or cooling.
https://www.partshnc.com/media/catalog/product/8/4/8403-062.jpg
Manufacturer Name: Bard HVAC
Product Number: 8403-062
OEM Part Number: 8403-062
Product Description: 10K Ohm Remote Air Snsr(Equip)
Weight:0.36lbs/163.29g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Bard HVAC 8403-062 Remote Air Sensor 10K Ohm
Your Rating
Customer Questions
What maintenance is required for the Bard HVAC 8403-062 Remote Air Sensor?

Inspect the remote air sensor regularly for loose wiring, dust buildup, or poor mounting contact that may affect temperature sensing accuracy. Keep the sensor housing clean and away from moisture or direct heat sources. Periodically verify resistance readings and secure terminal connections to maintain accurate HVAC temperature monitoring.

What are common issues with the Bard HVAC 8403-062 Remote Air Sensor?

  • Wiring loose or damaged causing inaccurate temperature readings.
  • Sensor drift or calibration loss over time leading to incorrect control signals.
  • Moisture intrusion causing corrosion or intermittent signal failure.
  • Dust buildup affecting response time and sensitivity.

Installation Steps

Step 1: Turn off HVAC power at breaker and verify no voltage.

Step 2: Select mounting location in return air path away from heat sources or drafts.

Step 3: Mount sensor base using screws and route low-voltage cable to control panel.

Step 4: Connect wires to sensor terminals on control board as per wiring diagram.

Step 5: Secure sensor, restore power, and verify temperature reading on controller display.