The Nordyne 1046593 Hot Surface Ignitor is an essential part in HVAC systems of the contemporary gas furnaces that are manufactured with specific reference to G6 series. In its capacity as a hot surface ignitor, it does away with the conventional standing pilot light, which is not only less efficient, but also less safe. This part uses a 120V electrical current to heat a resistive material such as silicon carbide or silicon nitride to a very high temperature, usually red hot. When the thermostat demands heat, this electrical current is applied on the ignitor so that it will heat up very quickly.
https://www.partshnc.com/media/catalog/product/1/0/1046593.jpg

Specifications

  • Type: Hot Surface Ignitor
  • Voltage: 120V
  • Compatibility: G6
Write Your Own Review
You're reviewing:Nordyne 1046593 Hot Surface Ignitor 120V G6
Your Rating
Customer Questions
What maintenance is required for the Nordyne 1046593 Hot Surface Ignitor?

Regularly inspect the ignitor for cracks or wear and clean it gently with a soft brush to remove debris. Ensure power is off before handling to prevent electric shock. Replace it immediately if damaged to maintain safe and efficient furnace operation. Periodic checks prevent ignition failure and costly repairs.

What are common issues with the Nordyne 1046593 Hot Surface Ignitor?

  • Ignitor not glowing or failing to ignite.
  • Cracks or physical damage to the element.
  • Intermittent ignition or delayed startup.
  • Electrical connection issues causing faulty operation.

Installation Steps

Step1: Turn off power and shut off the gas supply in the appliance for safety.

Step2: Remove the furnace access panel to reach the burner assembly.

Step3: Disconnect the old ignitor’s wiring harness carefully without excessive force.

Step4: Remove mounting screws and take out the old ignitor.

Step5: Install the new ignitor in the same position and secure with screws.

Step6: Reconnect the wiring harness, restore power and gas, and test ignition sequence.