Facebook Pixel

Burnham Boiler 104425-01 Pressure Switch - 2" WC

Special Price $38.72 Regular Price $50.34
In stock
SKU
104425-01
The Burnham Boiler 104425-01 Pressure Switch 2" WC is an essential part that plays an essential role in the operation of HVAC systems, especially boilers. This pressure switch is designed to switch at a pressure rating of 2.0" WC, which is the common pressure rating used in gas systems to achieve the right pressure level. The pressure switch monitors the pressure of the boiler system to ensure that it is safe. The switch cuts off the operation this way to prevent 3conditions such as overpressure beyond acceptable levels causing hazards such as overheating, or a release of gas.
https://www.partshnc.com/media/catalog/product/1/0/104425-01.jpg

Specifications

  • Weight:0.13lbs
  • Type: Pressure Switch
  • Pressure Rating: 2.0" WC
Manufacturer Name: Burnham Boiler
Product Number: 104425-01
OEM Part Number: 104425-01
Product Description: Pressure Switch 2.0"Wc
Weight:0.13lbs/58.97g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Burnham Boiler 104425-01 Pressure Switch - 2" WC
Your Rating
Customer Questions
What maintenance is required for the Burnham Boiler 104425-01 Pressure Switch?

Inspect wiring connections regularly and ensure the pressure sensing port remains free of debris or moisture buildup. Periodic testing confirms accurate switching operation. Ensure that heating system faults and ensures safe, accurate system performance.

What are common issues with the Burnham Boiler 104425-01 Pressure Switch?

  • Inaccurate pressure sensing causing short cycling.
  • Electrical contact failure or intermittent switching.
  • Blocked sensing port leading to improper readings.
  • System shutdown due to faulty pressure response.
  • Failure to activate at correct setpoint.

Installation Steps

Step 1: Turn off boiler power and gas supply; allow system to cool completely.

Step 2: Label and disconnect wiring from the existing pressure switch.

Step 3: Remove old switch and inspect tubing/vent connections for blockages.

Step 4: Install new switch securely and reconnect tubing and electrical terminals per wiring diagram.

Step 5: Restore power and gas slowly, then check proper pressure switch activation during ignition cycle.

Step 6: Check for leaks and ensure safe combustion operation before closing access panel.