Facebook Pixel

Nordyne 1017853R Evaporator Coil

Special Price $746.30 Regular Price $828.39
In stock
SKU
1017853R
The Nordyne 1017853R Evaporator Coil is a high-efficiency component intended for household and commercial HVAC systems. It plays a role in cooling by absorbing warm and passing it into the refrigerant that circulates through the system. As hot air moves across the coil, it cools down, becomes chilled air, then gets recycled to enhance comfort and air quality conditions. This coil can work with different Nordyne split systems and air handlers thus providing good performance with low energy consumption. Additionally, its design promotes an effective heat exchange process while reducing chances of system failures thus resulting in lower maintenance payments as well as lasting more years for HVAC units.
Manufacturer:
https://www.partshnc.com/media/catalog/product/1/0/1017853r_nordyne_partshnc.png

Specifications

  • Type: Evaporator Coil
    Manufacturer Name: Nordyne
    Product Number: 1017853R
    OEM Part Number: 1017853R
    Product Description: Evaporator Coil
    Weight:22.5lbs/10205.82g

    Choose the best HVAC equipment parts and supplies from PartsHnC!

    • Same Day Shipping

    • Best Quality And Best Price

    • Wide Range of Inventory

    • Best Customer Service

    Have More Questions or Need Help to Place The Order?
    Reach us at (866)773-0907 or [email protected]

    Write Your Own Review
    You're reviewing:Nordyne 1017853R Evaporator Coil
    Your Rating
    Customer Questions
    What maintenance is required for the Nordyne 1017853R Evaporator Coil?

    Clean evaporator coil regularly to prevent dust buildup and maintain heat transfer. Inspect fins, drain lines, and airflow to ensure smooth operation and avoid moisture issues. Schedule HVAC servicing and handle carefully to avoid coil damage.

    What are common issues with the Nordyne 1017853R Evaporator Coil?

    • Airflow restriction due to dirt or dust buildup.
    • Refrigerant leaks or low cooling performance.
    • Frozen coil from poor airflow or thermostat issues.
    • Drain clog causing water leakage.
    • Corrosion or fin damage affecting efficiency.

    Installation Steps

    Step 1: Turn off power to HVAC unit at breaker and verify no voltage.

    Step 2: Recover refrigerant safely using proper HVAC tools.

    Step 3: Remove old coil inspect air handler and fitment for compatibility.

    Step 4: Install new coil secure ensure correct airflow orientation and seal connections and verify seal integrity.

    Step 5: Reconnect refrigerant lines braze joints if needed pressure test for leaks.

    Step 6: Restore power and test cooling performance and thermostat response.