The Nordyne 1017207 DC Heater Relay Kit is an essential component for controlling heating components in Nordyne HVAC systems. It is designed to replace incorrect relays, providing full heating capacity and avoiding future failures. This kit has been designed for use with Nordyne heating systems, providing an easy connection and a constant performance. Made with fine materials, the relay kit is built to withstand industrial and commercial applications. Whenever you installed this kit , the HVAC system’s entire efficiency will increase causing lower energy consumption and improved heating ability. This Heater Relay Kit is a perfect option for maintaining the functionality and durability of Nordyne HVAC appliances.
Manufacturer:
https://www.partshnc.com/media/catalog/product/1/0/1017207.jpg

Specifications

  • Type: Relay Kit
  • Voltage: 24 VDC
  • Configuration: SPST
  • Amperage: 30A
Manufacturer Name: Nordyne
Product Number: 1017207
OEM Part Number: 1017207
Product Description: Dc Heater Relay Kit
Weight:0.25lbs/113.4g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nordyne 1017207 SPST DC Heater Relay Kit 24V
Your Rating
Customer Questions
What maintenance is required for the Nordyne 1017207 Heater Relay Kit?

Periodically inspect the relay for dust, corrosion, or loose wiring connections. Ensure terminals are clean and secure. Test the relay’s operation under power to confirm proper switching. Always disconnect power before servicing to avoid electrical hazards.

What are common issues with the Nordyne 1017207 Heater Relay Kit?

  • Relay fails to activate or switch.
  • Overheating of contacts under load.
  • Corroded or loose terminals.
  • Intermittent or inconsistent heater operation.

Installation Steps

Step 1: Turn off all power to the HVAC system before installation.

Step 2: Remove the existing relay, noting wiring connections for reference.

Step 3: Mount the new SPST DC relay securely in the designated location.

Step 4: Connect the control wiring following the manufacturer’s diagram.

Step 5: Ensure all connections are tight and comply with local electrical codes.

Step 6: Restore power and test the system, verifying the relay operates the heater correctly and safely.