Facebook Pixel

Lochinvar & A.O. Smith 100113158 Spark Module

Special Price $277.66 Regular Price $308.20
In stock
SKU
100113158
The Lochinvar & A.O. Smith 100113158 Spark Module is used to create sparks for ignition in HVAC systems particularly for commercial water heaters and boilers. It produces a strong sparking ability to ignite gas burners hence improving its reliability. It is built for longevity, meaning it has low maintenance and thus less time off the production line. This module can be incorporated into the various models and increases the efficiency as it guarantees the right ignition and flame stability. It assists in saving energy costs and at the same time ensuring a better heating performance by allowing faster starts and reducing fuel wastage.
https://www.partshnc.com/media/catalog/product/1/0/100113158.jpg

Specifications

  • Type: Spark Module
    Manufacturer Name: Lochinvar & A.O. Smith
    Product Number: 100113158
    OEM Part Number: 100113158
    Product Description: Spark Module
    Weight:0.84lbs/381.02g

    Choose the best HVAC equipment parts and supplies from PartsHnC!

    • Same Day Shipping

    • Best Quality And Best Price

    • Wide Range of Inventory

    • Best Customer Service

    Have More Questions or Need Help to Place The Order?
    Reach us at (866)773-0907 or [email protected]

    Write Your Own Review
    You're reviewing:Lochinvar & A.O. Smith 100113158 Spark Module
    Your Rating
    Customer Questions
    What maintenance is required for the Lochinvar & A.O. Smith 100113158 Spark Module?

    Regularly inspect the spark module for secure wiring connections and signs of wear or corrosion. Keep the surrounding area clean and free from dust or moisture. Ensure proper grounding and check ignition performance periodically to maintain safe and accurate operation.

    What are common issues with the Lochinvar & A.O. Smith 100113158 Spark Module?

    • Failure to ignite burner.
    • Weak or inconsistent spark output.
    • Loose or damaged wiring connections.
    • Intermittent ignition operation.
    • Electrical faults or short circuits.
    • Moisture-related malfunction or corrosion.

    Installation Steps

    Step 1: Turn off power and gas supply to the heater for safety carefully.

    Step 2: Remove access panel and locate the existing spark module.

    Step 3: Disconnect wiring harness carefully, noting original connections.

    Step 4: Install new module in same mounting position.

    Step 5: Reconnect wiring exactly as labeled before removal.

    Step 6: Secure panel, restore power, and test ignition spark.

    Step 7: Check operation and ensure no faults or abnormal sounds.