Facebook Pixel

Honeywell V8944C1033 1.5" 2-Stage LP Pressure Gas Valve 1-1/2" NPT

Special Price $703.99 Regular Price $781.43
In stock
SKU
V8944C1033
The Honeywell V8944C1033 1.5" two-stage low-pressure gas valve is designed for use in residential and light commercial HVAC systems. This valve, which is accurate about the gas flow to the burner, provides efficiency, along with safety. Two stages of operation are provided, which allow for precise modulation of the gas supply according to the heating demand. The two-stage operation adds to comfort by increasing the accuracy of temperature control and reducing temperature swings. This is often used in conjunction with gas furnaces, boilers and other gas-fired heating equipment. This includes improved efficiency, and better comfort, with safety shut-off mechanisms.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/0/0012866_0_3.jpg

Specifications

  • Type: Two-stage LP Gas Valve
  • Pipe Size: 1.5"

PRODUCT OVERVIEW:
Designed for liquid petroleum (LP) gas applications in commercial and industrial heating systems, this two-stage valve delivers precise fluid control. The Honeywell V8944C1033 regulates gas flow at low-fire and high-fire operating stages to match varying system demands. This 24 VAC valve features a 1-1/2-inch NPT connection and a slow-opening mechanism to ensure safe burner operation.

TWO-STAGE PRESSURE REGULATION:
The Valve provides separate low-fire and high-fire pressure regulation. The low-fire regulator has an adjustment range of 1.4–4.2 inches water column, with a factory setting of 1.4 inches water column. The high-fire regulator has an adjustment range of 8.8–11.5 inches water column, with a factory setting of 10 inches water column. These settings allow the valve to regulate LP gas pressure at two operating stages when used with compatible controls.

SLOW-OPENING OPERATION AND ELECTRICAL CONTROL:
The valve uses a slow-opening mechanism with an opening time of 3–25 seconds and a maximum closing time of 2 seconds under the specified test conditions. It operates on a 24 VAC control supply and uses 1/4-inch spade terminals with three 30-inch leadwires. The valve closes when electrical power is lost, supporting its gas shutoff function.

REPLACEMENT GUIDELINES:
Replace the valve if it leaks, fails to regulate gas pressure, does not open or close correctly, or causes unreliable burner operation. Before installation, verify the complete model number, LP gas application, 1-1/2-inch NPT connection, 24 VAC supply, two-stage control requirements, and required gas flow capacity. Gas valve installation, pressure adjustment, and leak testing must be performed by a qualified gas-service technician in accordance with the equipment manufacturer's procedures.

COMMON FAILURE SYMPTOMS:

  • Failure to ignite or maintain burner operation
  • Incorrect low-fire or high-fire gas pressure
  • Unstable burner operation between firing stages
  • Failure of the valve to open when commanded
  • Failure of the valve to close correctly
  • Gas leakage around the valve or its connections
  • Delayed or inconsistent gas flow during startup

EQUIPMENT COMPATIBILITY:
The Honeywell V8944C1033 is intended for compatible LP gas-fired heating equipment requiring a two-stage regulating diaphragm gas valve. The V8944 series is used in applications such as boilers, unit heaters, duct furnaces, makeup-air systems, and rooftop heaters. Confirm the exact equipment model, gas type, connection size, control voltage, firing-stage requirements, and required capacity before ordering.

TECHNICAL SPECIFICATIONS:
Product Identification:
Brand: Honeywell
Part Number: V8944C1033
Product Type: Two-Stage Pressure Regulating Gas Valve
Physical Specifications:
Inlet/Outlet Size: 1-1/2" NPT
Flow Pattern: Straight Through, Non-Offset
Pilot Tapping: 1/8"
Bleed Tappings: Two 5/16" UNF
Electrical Connections: 1/4" Spade Terminals with Three 30" Leadwires
Material Details:
Body Material: Aluminum
Operating Conditions:
Gas Type: LP Gas
Pressure Rating: 1/2 PSI
Operating Temperature Range: -40 to 150°F
Mounting Position: Upright Horizontal
Flow & Capacity Specifications:
Capacity: 500 to 1490 CFH
Valve Operation & Control:
Voltage: 24Vac
Opening Time: 3 to 25 Seconds
Closing Time: 2 Seconds Maximum
Opening Type: Slow Opening
Low Fire Setpoint Range: 1.4" to 4.2" W.C. (1.4" W.C. Factory Setting)
High Fire Setpoint Range: 8.8" to 11.5" W.C. (10" W.C. Factory Setting)

Write Your Own Review
You're reviewing:Honeywell V8944C1033 1.5" 2-Stage LP Pressure Gas Valve 1-1/2" NPT
Your Rating
Customer Questions
What is the Honeywell V8944C1033 gas valve used for?

The Honeywell V8944C1033 is a two-stage LP gas valve used to regulate gas pressure and flow in compatible heating equipment, including boilers, unit heaters, duct furnaces, makeup-air systems, and rooftop heaters.

Is the Honeywell V8944C1033 compatible with LP gas or natural gas?

The V8944C1033 is specified for liquefied petroleum (LP) gas. It should not be substituted into a natural gas system unless the equipment and valve documentation explicitly approves that application.

What are the low-fire and high-fire pressure settings on the V8944C1033?

The factory low-fire setting is 1.4 inches water column, adjustable from 1.4 to 4.2 inches water column. The factory high-fire setting is 10 inches water column, adjustable from 8.8 to 11.5 inches water column.

What voltage and pipe connection does the Honeywell V8944C1033 require?

The valve operates on 24 VAC at 50/60 Hz and uses a 1-1/2-inch NPT pipe connection.

How do I know if the Honeywell V8944C1033 needs replacement?

Replacement may be necessary if the valve leaks, fails to open or close correctly, produces incorrect gas pressure, or causes unreliable burner operation. A qualified technician should verify the valve model, LP gas application, electrical supply, and pressure settings before replacement.