Schneider Electric (Erie) 0453L0038GA00 2-Position Damper Actuator CW S/R 24VAC 45 in-oz

Special Price $126.03 Regular Price $144.94
In stock
SKU
0453L0038GA00
The Schneider Electric (Erie) 0453L0038GA00 Damper Actuator used as a 24V intended for light-duty HVAC system control. A linkage drive system operates in device to generate clockwise movement for airflow regulation. The device operates within air handling units and ventilation systems to modify dampers which control the airflow volume through ducts. The proper placement of dampers enables absolute temperature and pressure control which enhances energy conservation while providing comfortable indoor conditions. The actuator linkage design enables dependable movement which commercial buildings need to manage ventilation effectively.
https://www.partshnc.com/media/catalog/product/0/4/0453l0038ga00_schneider-electric-erie_partshnc.jpg

Specifications

  • Type: Damper Actuator
  • Voltage: 24VAC
  • Torque: 45 in-oz
  • Drive Type: Linkage Drive
  • Rotation: Clockwise (CW)
  • Return Type: Spring Return
  • Operation: Two-Position

PRODUCT OVERVIEW:
Controls damper positioning in HVAC systems by converting electrical input into mechanical movement. The Schneider Electric (Erie) 0453L0038GA00 2-Position Damper Actuator is a genuine OEM component that operates on 24 VAC and provides 45 in-oz of torque to move the connected damper between its two operating positions. Its clockwise spring-return design supports the specified direction of travel and return action.

DAMPER ACTUATION:
Rotational movement from the actuator positions the connected damper within the HVAC system. Its two-position operation moves the damper between defined open and closed positions, supporting controlled airflow through HVAC ductwork. The actuator's torque output helps drive the damper mechanism during operation.

SPRING-RETURN OPERATION:
When operating power is removed, the internal spring drives the actuator toward its designated return position. Its clockwise return direction determines how the connected damper moves during this process. This action supports the intended damper position during changes in the control signal or power availability.

REPLACEMENT GUIDELINES:
Replace the Schneider Electric (Erie) 0453L0038GA00 when the damper actuator fails to move the damper between its two positions, does not complete its spring-return movement, or cannot provide sufficient operating torque. Replacement may also be necessary if the actuator housing, drive connection, or internal mechanism is damaged. Have a qualified HVAC technician inspect the actuator, wiring, and damper linkage before replacement.

COMMON FAILURE SYMPTOMS:

  • Damper fails to move between its two operating positions
  • Actuator does not respond to the control signal
  • Spring-return movement is incomplete or fails
  • Damper movement becomes slow or inconsistent
  • Actuator produces unusual noise or shows physical damage

EQUIPMENT COMPATIBILITY:
The Schneider Electric (Erie) 0453L0038GA00 is a genuine OEM actuator intended for HVAC damper-control applications requiring a two-position actuator with clockwise spring return. Its operating voltage, torque output, rotation direction, and mounting arrangement must match the connected damper and control system. Check the existing actuator part number and application requirements to confirm suitability.

TECHNICAL SPECIFICATIONS:
Brand: Schneider Electric (Erie)
Part Number: 0453L0038GA00
Product Type: 2-Position Damper Actuator
Operating Voltage: 24 VAC
Torque: 45 in-oz

Write Your Own Review
You're reviewing:Schneider Electric (Erie) 0453L0038GA00 2-Position Damper Actuator CW S/R 24VAC 45 in-oz
Your Rating
Customer Questions
What maintenance is required for the Schneider Electric (Erie) 0453L0038GA00 Damper Actuator?

Regularly inspect the actuator for dust, dirt, or mechanical obstruction. Verify that linkages move freely and tighten any loose connections. Check electrical wiring and test operation to ensure smooth damper control and prevent malfunctions.

What are common issues with the Schneider Electric (Erie) 0453L0038GA00 Damper Actuator?

  • Failing to respond to control signals.
  • Noisy or stiff movement of the linkage.
  • Inaccurate damper positioning.
  • Electrical connection faults or voltage inconsistencies.

When should the Schneider Electric (Erie) 0453L0038GA00 damper actuator be replaced?

Replacement may be necessary if the actuator repeatedly stalls, fails electrical testing, or cannot complete its operating cycle. Persistent failure after checking the power supply and damper mechanism warrants further inspection.

What is the primary function of the 0453L0038GA00 damper actuator?

It converts electrical power into mechanical movement to operate an HVAC damper. Its two-position design provides controlled movement between the designated damper positions.

What maintenance is recommended for this damper actuator?

Periodically check the actuator enclosure for cracks, moisture intrusion, and environmental deterioration. Ensure its mounting hardware remains intact and the installation area is free from excessive contamination.

What are the main technical specifications of the 0453L0038GA00 actuator?

The actuator has a 24VAC operating voltage and a torque rating of 45 in-oz. It features clockwise (CW) rotation, spring-return (S/R) operation, and two-position control.

How can I verify whether this actuator is suitable for my HVAC equipment?

Compare the actuator's model reference with the replacement part specified in the equipment manufacturer's parts documentation. Confirm the required operating sequence and mechanical interface before installation.

Installation Steps

Step1: Power off the HVAC system to ensure safety.

Step2: Remove the old actuator by loosening mounting screws and disconnecting control wiring.

Step3: Position the new Electric actuator on the damper linkage.

Step4: Reconnect wiring according to the original setup.

Step5: Secure the actuator with screws, ensuring proper alignment with the damper.

Step6: Power on the system and test damper movement and control signals.

Step7: Verify smooth operation before starting normal system use.