Facebook Pixel

Goodman 0151R00185S Open Service Valve 3/4 Inch

Special Price $36.02 Regular Price $41.95
In stock
SKU
0151R00185S
The Amana-Goodman 0151R00185S Open Service Valve is a crucial component for controlling water flow in HVAC systems. Made of durable brass, it features a 3/4-inch diameter opening and can withstand temperatures ranging from -40°F to 86°F. This valve allows technicians to isolate sections of the water system for maintenance or repairs without affecting the entire system. It operates at a frequency of 50/60 Hz, compatible with most standard HVAC electrical setups. The Open Service Valve provides several benefits for HVAC systems. Firstly, it simplifies maintenance by enabling technicians to shut off water flow to specific areas, minimizing water waste and potential damage during repairs. Secondly, it enhances system control by allowing for isolation of specific zones for adjustments or repairs without impacting the entire system's operation. This targeted approach improves efficiency and reduces downtime. Finally, the brass construction ensures long-lasting durability, making the Amana-Goodman 0151R00185S a reliable choice for technicians and homeowners alike.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/1/0151r00185s.jpg

Specifications

  • Size: 3/4Inch
  • Material: Brass
  • Temperature Range (F)/(c): -40°F-+86°F
  • Weight: 0.73lbs
  • Frequency: 50/60 Hz
Manufacturer Name: Amana-Goodman
Product Number: 0151R00185S
OEM Part Number: 0151R00185S
Product Description: 3/4" Open Service Valve
Weight:0.73lbs/331.12g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Goodman 0151R00185S Open Service Valve 3/4 Inch
Your Rating
Customer Questions
What maintenance is required for the Goodman 0151R00185S Open Service Valve?

Inspect the valve regularly for refrigerant or gas leaks, corrosion, and worn seals around the service ports. Ensure valve stems are properly tightened and capped after servicing. Routine inspection helps maintain system efficiency, prevents refrigerant loss, and supports safe HVAC operation under pressure.

What are common issues with the Goodman 0151R00185S Open Service Valve?

  • Valve stem seizing or difficulty turning.
  • Worn or damaged internal seals.
  • Loss of pressure retention in service port.
  • Improper sealing after maintenance causing slow leaks.

Installation Steps

Step 1: Shut off HVAC power and refrigerant system; recover refrigerant safely using proper equipment.

Step 2: Remove old valve and clean service port threads.

Step 3: Align new valve with correct orientation and secure fittings tightly.

Step 4: Braze connections using proper nitrogen purge to avoid oxidation.

Step 5: Check for leaks with pressure test and soap solution.

Step 6: Restore system and monitor operation.