Amana-Goodman 0131P00057SP PTAC Indoor Blower Motor

Special Price $71.05 Regular Price $81.70
In stock
SKU
0131P00057SP
The Amana-Goodman 0131P00057SP PTAC Indoor-Blower Motor is an essential component of your PTAC packaged terminal air-conditioner system. This motor is used to power the fan that is used in circulating air around your room. It effectively blows air crossed the evaporator evaporator coils where the heat is isolated and then circulates the cool air around the room. This guarantees both the equal distribution of HVAC system and a favorable climate within the premises. Advantages of this motor are: It has a dependable performance and, low noise level, and it is suitable for many Amana-Goodman PTAC units.
https://www.partshnc.com/media/catalog/product/0/1/0131p00057sp_amana-goodman_partshnc.png

Specifications

  • Type: Indoor Blower Motor
    Manufacturer Name: Amana-Goodman
    Product Number: 0131P00057SP
    OEM Part Number: 0131P00057SP
    Product Description: Ptac Indoor Blower Motor
    Weight:2.78lbs/1260.99g

    Choose the best HVAC equipment parts and supplies from PartsHnC!

    • Same Day Shipping

    • Best Quality And Best Price

    • Wide Range of Inventory

    • Best Customer Service

    Have More Questions or Need Help to Place The Order?
    Reach us at (866)773-0907 or [email protected]

    Write Your Own Review
    You're reviewing:Amana-Goodman 0131P00057SP PTAC Indoor Blower Motor
    Your Rating
    Customer Questions
    What maintenance is required for the Amana-Goodman 0131P00057SP Blower Motor?

    Regularly clean dust and debris from the blower motor and surrounding area to maintain airflow. Check for unusual noises or vibrations, and ensure all electrical connections are secure. Lubricate bearings if accessible and follow safety precautions when handling electrical components.

    What are common issues with the Amana-Goodman 0131P00057SP Blower Motor?

    • Reduced airflow.
    • Excessive noise or rattling.
    • Motor overheating or failure.
    • Vibration or wobbling during operation.

    Installation Steps

    Step 1: Disconnect power completely and confirm no electrical current is present.

    Step 2: Access the motor area and carefully label all wiring connections.

    Step 3: Remove the existing blower motor, keeping mounting hardware safe.

    Step 4: Install the new blower motor in the same position and secure firmly.

    Step 5: Reconnect wiring exactly as labeled to avoid errors.