Facebook Pixel

Raypak 006725F Surface Mount Limit 135F

Special Price $61.29 Regular Price $70.49
In stock
SKU
006725F
Raypak 006725F Surface Mounted Thermostat for exact temperature control in HVAC systems pool heaters, and boilers. It has an automatic reset feature to maintain efficient temperature control by turning on or off heating elements at a set temperature of 135°F. It helps maintain better heating performance prevents overheating and enhances energy efficiency. Its heating equipment uses it for reliable operation and extended system durability. With its surface mount design, the thermostat is and is a better low way to maintain a constant water or air temperature in residential and commercial heating applications.
https://www.partshnc.com/media/catalog/product/0/0/006725f.jpg

Specifications

  • Type: Surface Mount Limit
  • Temperature Rating: 135°F

PRODUCT OVERVIEW:
Monitors temperature conditions within designated Raypak pool and spa heaters to provide high-limit protection against excessive heat. The Raypak 006725F Surface Mount Limit 135°F is an OEM temperature-responsive safety control that opens its electrical contacts when the monitored temperature reaches its specified trip point. Its surface-mounted arrangement allows it to respond to temperature at the designated mounting location, while its 135°F rating identifies the threshold associated with its limit-control function. This protective switching action helps interrupt heater operation when the monitored temperature exceeds the permitted limit.

TEMPERATURE SWITCHING:
Responds to temperature changes at the switch's mounting location through an automatic electrical contact mechanism. When the monitored temperature reaches the switch's activation threshold, the contacts open to interrupt the associated control circuit. As the temperature decreases sufficiently, the automatic-reset mechanism allows the contacts to return to their closed state. This operation provides automatic temperature-responsive switching without requiring manual resetting.

HEATER TEMPERATURE PROTECTION:
Provides high-limit protection within the pool heater's temperature-control arrangement. When the switch opens its contacts, the associated control circuit interrupts the heating operation, preventing continued burner operation under the detected high-temperature condition. The switch works alongside the heater's other operating and safety controls, contributing to temperature-related protection during normal heating operation.

REPLACEMENT GUIDELINES:
Replace the Raypak 006725F Surface Mount Limit 135°F when electrical contact failure, physical damage, or deterioration prevents the switch from responding correctly to temperature changes. Contacts that open prematurely, fail to reset after cooling, or do not open at the designated temperature can cause repeated heating interruptions or compromise high-limit protection. A qualified pool heater technician should inspect the switch and investigate the cause of repeated high-limit activation before replacement.

COMMON FAILURE SYMPTOMS:

  • Pool heater repeatedly shuts down due to high-limit activation.
  • Heating stops before the water reaches the thermostat's target temperature.
  • Heater fails to resume operation after the temperature decreases.
  • High-limit fault indication appears during heater operation.
  • Heating cycles become inconsistent due to repeated safety-control interruptions.
  • Heater operation remains interrupted after the switch should have reset

EQUIPMENT COMPATIBILITY:
The Raypak 006725F OEM Surface Mount High-Limit Control is rated for 135°F operation and intended for designated Raypak pool and spa heater applications requiring an automatic-reset, surface-mounted temperature limit switch. Verify the complete heater model number, header configuration, original OEM control part number, temperature rating, and reset type against Raypak manufacturer parts documentation before selecting this control.

TECHNICAL SPECIFICATIONS:
Brand: Raypak
Part Number006725F
Product Type: Surface Mount High-Limit Switch
Temperature Rating: 135°F

Write Your Own Review
You're reviewing:Raypak 006725F Surface Mount Limit 135F
Your Rating
Customer Questions
What maintenance is required for the Raypak 006725F Thermostat?

Regularly inspect the thermostat for dust, corrosion, or loose connections and clean gently with a dry cloth. Proper maintenance ensures accurate temperature readings and safe operation. Avoid applying excessive force to the mounting or adjustment components.

What are common issues with the Raypak 006725F Thermostat?

  • Failure to reset automatically.
  • Inaccurate temperature readings.
  • Loose or corroded electrical connections.
  • Physical damage to the mounting or sensor.

What does the Raypak 006725F surface mount limit switch do?

The Raypak 006725F provides high-temperature protection for Raypak pool and spa heaters. It monitors temperature at its mounting location and interrupts heating operation when the specified 135°F limit is reached.

Is the Raypak 006725F an automatic-reset high-limit switch?

Yes. The 006725F is an automatic-reset high-limit switch. Its contacts return to their normal operating state after the temperature decreases sufficiently following a high-limit event.

Can a faulty Raypak 006725F cause a pool heater to stop heating?

Yes. A malfunctioning high-limit switch may interrupt heating if its contacts remain open or respond inconsistently to temperature changes. Similar symptoms can also result from other heater operating conditions.

What does surface-mount mean for the Raypak 006725F limit switch?

Surface-mount identifies the switch's mounting style. The mounting arrangement should match the heater's designated switch location and the existing installation requirements.

What should I verify before ordering the Raypak 006725F limit switch?

Verify the 006725F part number, 135°F temperature rating, automatic-reset operation, and surface-mount design against the existing switch and Raypak heater parts documentation.

Installation Steps

Step1: Turn off power to the system before installation.

Step2: Remove any old thermostat and clean the mounting area.

Step3: Attach the new thermostat securely using the provided screws.

Step4: Connect the electrical wires according to the wiring diagram.

Step5: Ensure all connections are tight and safe.

Step6: Restore power and test the thermostat for proper operation.