The Williams Comfort Products P043801 Pilot Generator/Thermopile Thermocouple is a part of gas powered HVAC systems that creates millivoltage power to operate gas valves without external electricity. The pilot generator used is a thermopile type compatible with many Williams Comfort Products wall furnaces and room heaters. This converts the pilot flame's heat to electrical energy and in itself it is working safely and has a long life. Its main features include energy efficiency, safety and dependable performance and therefore is suitable for maintaining constant heating in residential or light commercial applications with pilot ignition systems.
https://www.partshnc.com/media/catalog/product/p/0/p043801.jpg

Specifications

  • Type: Pilot Generator/Thermopile Thermocouple
  • Model: P043801
Manufacturer Name: Williams Comfort Products
Product Number: P043801
OEM Part Number: P043801
Product Description: Thermocouple
Weight:0.13lbs/58.97g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Williams Comfort Products P043801 Pilot Generator/Thermopile Thermocouple
Your Rating
Customer Questions
What maintenance is required for the Williams Comfort Products P043801 Thermopile Thermocouple?

Regularly inspect the thermocouple for soot, corrosion, or physical damage. Clean contacts gently and ensure proper alignment with the pilot flame. Verify electrical connections are secure and dry to maintain accurateignition and accurate temperature sensing.

What are common issues with the Williams Comfort Products P043801 Thermopile Thermocouple?

  • Pilot failing to ignite or stay lit.
  • Weak or inconsistent voltage output.
  • Soot buildup affecting sensor accuracy.
  • Loose or misaligned connections.

Installation Steps

Step 1: Turn off all power and shut off the gas supply for safety.

Step 2: Remove the access panel and locate the existing pilot assembly.

Step 3: Disconnect the old thermocouple from the gas valve and pilot generator.

Step 4: Install the new thermocouple, ensuring proper positioning in the pilot flame.

Step 5: Reconnect the thermocouple to the gas valve and pilot generator.