Facebook Pixel

Cleveland Controls NS2-1563-03 Pressure Switch

Special Price $62.92 Regular Price $72.36
Out of stock
SKU
NS2-1563-03
The Cleveland Controls NS2-1563-03 Pressure switch is applied in HVAC systems for measuring the flow or pressure. It works based on the variation of pressure between two points. When this pressure differential gets to a certain setpoint, the switch makes an electrical contact and can then operate other equipment. This switch is commonly used in HVAC equipment such as a furnace, an air handler, or a rooftop unit which the part checks the functionality of the fans and filters. Confirming that the system has enough airflow to perform optimally and safely, protecting equipment from damage due to blocked filters or failed fans, and preventing the use of heating elements without proper airflow.
https://www.partshnc.com/media/catalog/product/n/s/ns2-1563-03_-_nc.png

Specifications

  • Type: Pressure Switch
    Manufacturer Name: Cleveland Controls
    Product Number: NS2-1563-03
    OEM Part Number: NS2-1563-03
    Product Description: Pressure Switch
    Weight:0.09lbs/40.82g

    Choose the best HVAC equipment parts and supplies from PartsHnC!

    • Same Day Shipping

    • Best Quality And Best Price

    • Wide Range of Inventory

    • Best Customer Service

    Have More Questions or Need Help to Place The Order?
    Reach us at (866)773-0907 or [email protected]

    Write Your Own Review
    You're reviewing:Cleveland Controls NS2-1563-03 Pressure Switch
    Your Rating
    Customer Questions
    What maintenance is required for the Cleveland Controls NS2-1563-03 Pressure Switch?

    Regularly inspect the pressure switch for dust, corrosion, or loose connections. Test the switch periodically to ensure proper activation and responsiveness. Keep it clean and dry, and replace it immediately if signs of wear or malfunction appear to maintain system safety and performance.

    What are common issues with the Cleveland Controls NS2-1563-03 Pressure Switch?

    • Inaccurate pressure readings.
    • Sticking or sluggish switch operation.
    • Corrosion on terminals or contacts.
    • Failure to trigger at set pressure points.

    Installation Steps

    Step1: Turn off power and shut off equipment air or pressure supply.

    Step2: Depressurize the system before accessing the old switch.

    Step3: Disconnect tubing and wires from the existing pressure switch.

    Step4: Remove mounting screws and take out the old switch.

    Step5: Mount the new switch and reconnect tubing and wiring correctly.

    Step6: Restore pressure and power, then test the switch for proper activation.