Nordyne 922170 AC Compressor R-22 31,300 BTU 208/230V/1PH
Specifications
- Type: Compressor
- Refrigerant: R-22
- Cooling Capacity: 31,300 BTU
- Voltage: 208/230V
- Phase: 1PH
Loyalty ProgramStep 1: Turn off power at breaker and verify zero voltage with meter.
Step 2: Recover refrigerant per regulations using certified equipment.
Step 3: Remove old compressor, label and disconnect electrical and refrigerant lines.
Step 4: Mount new compressor securely on vibration pads in condenser unit.
Step 5: Braze refrigerant lines, pull vacuum, and leak test system.
Step 6: Restore power and check operating pressures and amp draw; ensure safe operation.