Loyalty ProgramStep 1: Turn off gas supply and electrical power, confirm no gas leakage.
Step 2: Remove old valve and clean pipe threads thoroughly.
Step 3: Align new gas valve with inlet/outlet flow direction.
Step 4: Apply gas-rated thread sealant and tighten securely.
Step 5: Reconnect wiring harness per the diagram.
Step 6: Restore gas supply, test for leaks with solution and verify ignition.