The Navien Tankless Water Heaters 30028036A Flame Rod is an essential part of flame sensing for proper flame identification in HVAC equipment including Navien Tankless Water Heatersand condensing boilers. This is a stainless flame rod with precise flame detection technology, which is safe for use. The flame rod works by producing a small voltage through which the system can confirm that there is burning. The mechanism will shut down to eliminate any danger if there is no flame. This rod helps to maintain the heating equipment at its better performance level by ensuring proper flame recognition.
https://www.partshnc.com/media/catalog/product/3/0/30028036a_navien-tankless-water-heaters_partshnc.jpg

Specifications

  • Type: Flame Rod
  • Weight: 0.18 lbs
  • Material: Stainless Steel
Manufacturer Name: NAVIEN TANKLESS WATER HEATERS
Product Number: 30028036A
OEM Part Number: 30028036A
Product Description: Flame Rod
Weight:0.18lbs/81.65g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Navien Tankless Water Heaters 30028036A Flame Rod
Your Rating
Customer Questions
What maintenance is required for the NAVIEN 30028036A Flame Rod?

Inspect the flame rod regularly for soot or corrosion and clean it gently with a soft cloth or fine sandpaper. Ensure proper positioning in the burner assembly for accurate flame detection. Regular maintenance helps prevent ignition errors and ensures safe operation. Always turn off power before servicing.

What are common issues with the NAVIEN 30028036A Flame Rod?

  • Ignition failure or burner not lighting.
  • Erratic flame detection or flame sensor errors.
  • Soot buildup causing false flame signal.
  • Corrosion reducing sensitivity.

Installation Steps

Step 1: Turn off the boiler and disconnect power and gas supply for safety.

Step 2: Open the unit’s front panel to access the burner assembly.

Step 3: Locate the existing flame rod and disconnect its wire lead.

Step 4: Unscrew and carefully remove the old flame rod from its mount.

Step 5: Install the new flame rod in the same position and secure it.

Step 6: Reconnect the wire lead firmly.

Step 7: Close the panel, restore power and gas, and test for proper ignition.